iGS-100 Day & Night Co2 Control with Auxiliary Output

iGS CO2 Control w Auxiliary Shut Off Output [ iGS-100] Maximum load both outputs: 15 A 120 Vac Battery-backed microprocessor control Sensor and Control range : 0-5000 ppm Automatic differential compensation: 20 ppm Annual drift of the CO2 sensor: 75 ppm Calibration of the CO2 sensor: 1 year The iGS-100 CO2 controller is an essential control tool to efficiently and economically use CO2 enrichment for higher growth rates or to fulfill minimum ventilation needs day and night. The display shows the ambient CO2 concentration within 75ppm at all times. The internal CO2 infra-red sensor reads values from 0 to 5000 ppm. The air sampling is optimized by means of an integrated fan. The control unit can be positioned up to 6 feet from the output box (a cable up to 50 feet can be used). The controller will automatically adjust its operating differential when the CO2 concentration overshoots or undershoots the desired set point. Two set points are used by the controller : day and night set points. This unit is 120 volts and uses 12 watts of power. CSA/UL compliant

Made In Canada
3 year Warranty

Adjustable separate set points for day and night / Auxiliary output


  • Easy to use CO2 enrichment or CO2 ventilation controller
  • Day/night detection
  • Adjustable separate set points for day and night from 0 to 4,900 ppm
  • Precise CO2 sensor: truly ±75 ppm
  • Yearly easy calibration by the user when prompted on display
  • An auxiliary output can shut-off or turn on another equipment while CO2 process is ongoing and a shut-off or turn on additional delay can be set (5 to 20 minutes)
  • Automatic adjustment of operational differential to keep conditions closest to set points
  • Operating hints: Allow you to check up your CO2 set-up performanceImage de iGS-25 Plug'N'Grow
  • 120 V, 15 A, 2 HP total load capacity
  • CSA/UL compliant

  For a correct calibration of the CO2 sensor at all times, use a 1000 ppm certified calibration gas.

Control CO2 enrichment with highest priority and temperature or humidity

Plug a PLUG'n'GROW temperature or humidity controller (iGS-021 or iGS-110) in iGS-100 output 2 (auxiliary output) and plug CO2 control equipment in iGS-100 output 1. Plug temperature or humidity adjusting equipment in temperature or humidity controller. By choosing operating mode 1-01 for iGS-100 output 1 and 2-21 for output 2 (or 2-22, 2-23, 2-24, 2-25 for a 5, 10, 15, 20 minutes OFF delay after CO2 enrichment), you will be able to add CO2 in your grow room during the day (when there's light) and to control temperature or humidity during the day (when output 1 is OFF) and at night.